The FAAC 624BLD electronic control unit is tailored for 230V vehicle barriers and is compatible with all FAAC 620 barrier models. It supports a variety of operational logics and programmable functions, including pause time, thrust levels, and working time. This unit offers robust terminal board inputs and outputs and features programming keys for easy configuration.
Downloads
MANUALS
Model |
624BLD |
---|---|
Power supply voltage |
220-240V~ 50/60 Hz |
Max. power |
7 W |
Motor max power |
300 W |
Max. accessories load |
500 mA |
Accessories power supply |
24V |
Programming |
3 keys (+, -, F) and display |
Operating logic |
Automatic, Automatic 1, Semi-automatic, Parking, Parking-Automatic, Condominium, Condominium-Automatic, FAAC-CITY, Manned, Remote, Custom |
Programmable functions |
Logic, Pause time, Thrust, Loop l and 2, Torque at initial thrust, Pre-flashing, Slow Closing, Deceleration time, Work time, LED output, Failsafe output, Status output, BUS output, Service Request |
Work time |
Programmable (from 0 to 4 min) |
Pause time |
Programmable (from 0 to 4 min) |
Thrust power |
Programmable on 50 levels |
Terminal board inputs |
Loop 1, Loop 2, Open, Close,Safety in closing, Stop, Emergency, 230V~ Power supply + Earth |
Terminal board outputs |
Flashing lamp, fan, motor, 24V power supply, fail-safe, status output, 24 Vdc indicator light, BUS, 4 programmable outputs in 18 different functions |
Rapid connector |
5-pin fitting for MINIDEC, DECODER or RP/RP2 receiver, Opening and closing limit switches, motor capacitor, beam release sensor |
Integrated detector 2 independent channels |
Real time self-calibration, sensitivity independent from loop geometry, loop operating frequency adjustment, message of “loop engaged” with LED display, loop status can be directed to programmable outputs, adjustment time over 2 levels. |
Protection Fuses |
F1=F 5A-250V~ F2=T 0.8A-250V~ |
Operating ambient temperature |
-20°C ÷ +55°C |